CIE x048-OP22

$28.88

Sale!
-50%

CIE x048-OP22

$28.88

USER EVALUATIONS OF CONTRAST-DOMINANT DISCOMFORT GLARE IN DIM DAYLIT SCENARIOS: PRELIMINARY FINDINGS
Conference Proceeding by Commission Internationale de L'Eclairage, 09/29/2021

Category:

Description

Discomfort glare metrics typically consider at least one of the two effects of discomfort glare – saturation and contrast – in their equation. The former occurs when there is an excessively bright glare source in the field of view, while the latter occurs when there is a high luminance ratio between the glare source and the adaptation level of the eye. We hypothesize that the contrast effect may dominate in low-light scenarios such as those commonly found in open-plan offices. Thus, we designed and carried out a user study in controlled laboratory conditions with 63 participants with a total of 252 scenes to investigate discomfort glare evaluations in dim daylight office environments with low adaptation levels. Our preliminary findings support our hypothesis that contrast-driven metrics predict glare responses in a more reliable way than hybrid metrics at low adaptation levels where the contrast effect dominates, which underlines the need for refining glare metrics in low brightness conditions.

Product Details

Published:
09/29/2021
Number of Pages:
12
File Size:
1 file , 1.7 MB